DT165T-DT265T LV Pole mounted circuit break

The protection and management of MV/LV transformers in rural areas requires the use of specific circuit breakers adapted to significant load imbalances, and thus guarantees complete power usage even in unbalanced conditions. These devices (4 poles, three of which are protected) use air-break technology with chambers with metal partitions to cut the arc. Low voltage pole mounted circuit breaker D165T – D265T with a digital trip unit.

Pouduct Name

Circuit breaker Low voltage pole mounted circuit breaker D165T with digital trip unit

Description

The protection and management of MV / LV transformers in rural areas requires the use of specific Circuit Breakers adapted to significant load imbalances and thus guarantees the total use of the installed power even in unbalanced conditions. These devices (4 poles – 3 protected) use air-break technology with chambers with metal partitions to cut the arc

Benefits

1.Transformer protection (50 kVA or 100 kVA) more compact and easier to use than a fused solution

2.When the Circuit Breaker is closed, a spark gap limits the rise in potential of the LV neutral from the earth, for a value exceeding 10 kV

3.When the Circuit Breaker is open, an electrical connection is done between the neutral of the transformer and the ground

4.Contact us to define your needs (number of feeders, fixing support, type of rod assembly, Trip Unit type, Load Indicator option, etc.)

Pole Circuit Breaker

CIRCUIT B REAKERS
D165T D265T
Strandard HN 63-S-11 HN 63-S-11
Rated Voltage 440 V 440 V
Rated Current 165 A 265 A
Rated short-circuit breaking capacity Rated short-circuit making current 4 000 A

6 800 A

6 400 A

11 700 A

Number of poles 4 4
Number of outputs 1 ouput 2 outputs
Cables cross-sections 25 / 70 mm2 50 / 150 mm2
Rated power-frequency withstand voltage (50Hz – 1min)  

4 kV

 

4 kV

  • Phase / Phase
  • Phase /Earth
10 kV 10 kV
Rated lightning impulse withstand voltage (1.2/50µs) 20 kV 20 kV
Control system Manual Manual
Installation Middle or Top pole Middle or Top pole

 

Digital Trip Unit

P  = 50 kVA P = 100 kVA  

 

Trip time

P = 160 kVA  

 

Trip time

U = 440 V U = 440 V U = 440 V
I = 72,2 A I = 144,3 A I =  231 A
Current in each phase (in A) Current in each phase (in A) Current in each phase (in A)
1 2 3 1 2 3 Min Max 1 2 3 Min Max
Temperature = + 20 °C
Initial load 48 48 48 96 96 96 155 155 155
 

 

Three-phases

85 85 85 170 170 170 1 h 35  

1 h 10

280 280 280 55 mn  

1 h 10

100 100 100 200 200 200 25 mn 320 320 320 26 mn
160 160 160 320 320 320 30 s 6 mn 500 500 500 30 s 7 mn 30 s
balanced overload 950 950 950 1900 1900 1900 0,02 s 0,2 s 3000 3000 3000 0,02 s 0,1 s
 

2000

 

2000

 

2000

 

4000

 

4000

 

4000

 

0,02 s

 

0,05 s

5640 5640 5640 0,015 s 0,025 s
6400 6400 6400 0,015 s 0,020 s
 

Three-phases

58 58 120 116 116 240 1 h 50  

50 mn

185 185 400 32 mn  

33 mn

58 58 160 116 116 320 15 mn 185 185 500 11 mn
unbalanced overload 58 58 220 116 116 440 30 s 7 mn 185 185 700 30 s 4 mn
0 0 950 0 0 1900 0,02 s 0,2 s 0 0 3000 0,02 s 0,1 s
Temperature = – 25 °C
Initial load 76 76 76 152 152 152 240 240 240
Three-phases 110 110 110 220 220 220 1 h  

44 mn

350 350 350 1 h  

45 mn

balanced overload 130 130 130 260 260 260 14 mn 420 420 420 14 mn
190 190 190 380 380 380 30 s 5 mn 600 600 600 30 s 5 mn
Three-phases 87 87 130 174 174 260 2 h 15  

30 mn

280 280 420 2 h 15  

48 mn

unbalanced overload 87 87 180 174 174 360 10 mn 280 280 560 13 mn
87 87 240 174 174 480 30 s 6 mn 280 280 760 40 s 5 mn 40 s
Temperature = + 50 °C
Initial load 25 25 25 50 50 50 80 80 80
Three-phases 70 70 70 140 140 140 1 h 30  

1 h 07

231 231 231 1 h 05  

1 h 05

balanced overload 90 90 90 180 180 180 20 mn 300 300 300 17 mn
160 160 160 320 320 320 45 s 5 mn 500 500 500 35 s 5 mn 40 s
Three-phases 48 48 100 96 96 200 1 h  

1 h

155 155 320 1 h  

1 h

unbalanced overload 48 48 130 96 96 260 15 mn 155 155 420 15 mn
48 48 200 96 96 400 30 s 7 mn 155 155 650 30 s 7 mn